Overview Product Description LOW TEMPERATURE V-TYPE SWIMMING POOL HEAT PUMP LASWIM low temperature V-type commercial swi;
Basic Info
Model NO. LAS-KP-V
Certification CE
Heat Source Type Air Source Heat Pump
Transport Package Carton
Specification 1400*900*1600(mm)
Trademark Laswim
Origin China
Product Description
Product Description

LOW TEMPERATURE V-TYPE SWIMMING POOL HEAT PUMP

LASWIM low temperature V-type commercial swimming pool heat pump is specially designed for commercial applications in low temperature areas.

It works with high efficient even under -10ºC(-30ºC EVI heat pump is available). This series heat pump is widely used for pools in hotels, SPA, water parks, gyms, competition pool, etc.

Features

1.Intelligent control for constant pool water temperature(max 40ºC)

2.Wide working air temperature range: -10ºC to 45ºC.

3.Anti-corrosion titanium in PVC heat exchanger for durable use.

4.Adopts V-type evaporator, with large heat exchanging surface and great heat absorption.

5.Multiple protections for safe operation and long service life.

6.The housing adopts high-quality galvanized sheet, with strong corrosion resistance.

7.Powerful centralized control and remote control is available for convenient operation and maintenance.

8.Automatic and forced defrosting function.

Product Parameters
Model LAS35-KP-VLAS42-KP-VLAS52-KP-VLAS70-KP-VLAS85-KP-VLAS105-KP-VLAS140-KP-VLAS180-KP-VLAS210-KP-V
Standard heating conditionHeating kW40.248.256.380.496.4112.6160.8192.8225.2
capacity
COP5.585.585.585.585.585.585.585.585.58
Low temperatureHeating kW28.133.739.356.267.478.6112.4134.8157.2
heating condition 1capacity
COP3.913.913.913.913.913.913.913.913.91
Low temperatureHeating kW23.928.733.547.857.46795.6114.8134
heating condition 2capacity
COP3.323.323.323.323.323.323.323.323.32
Cooling conditionCooling kW26.832.237.553.664.475107.2128.8150
capacity
EER3.23.23.23.23.23.23.23.23.2
Power supplyV/ph/Hz380V/3N/50Hz
Rated input powerkW7.28.610.114.417.220.228.834.440.4
Rated input currentA12.214.617.124.429.234.248.858.468.4
Max. Input powerkW11.814.216.523.628.43347.256.866
Max. Input currentA19.823.827.739.647.655.478.295.2110.8
Max. outlet water temperatureºC40
Operating air temperatureºC-10~45
Heat exhangerTitanium in PVC heat exchanger
Max. pressure MPa2.8/4.2
Refrigerant R22/R410A
Noise leveldB(A)≤64≤64≤65≤66≤67≤68≤70≤71≤71
Water inlet/outlet sizemm505050505050656565
Circulating Water flow ratem³/h8.610.412.117.320.724.234.641.548.4
Water pressure dropkPa404142636869525354
Net weightKg330350410600680750100010501180
Net dimension L*W*Hmm1400*900*16001400*900*16001400*900*16001900*1000*19601900*1000*19601900*1000*19601900*2000*19601900*2000*19601900*2000*1960

Remark:

1.A20/W26 condition :20ºC DB, 15ºC WB, inlet water temperature 26 ºC;2.A2/W26 condition: 2ºC DB, 1ºC WB,inlet water temperature 26ºC;3.A-6/W26 condition: -6ºC DB,-7ºC WB,inlet water temperature 26ºC;4.Cooling condition: 35ºC DB,24ºC WB,inlet water temperature 26 ºC;Due to the continuous improvement of products, the actual data will be subject to change,please refer to the nameplate.